The SORIWA Header Track

Made from recycled cellulose fibre –
Compatible with the SORIWA Multi-System

The SORIWA Header Track is a prefabricated component made from recycled fiberboard and complements the SORIWA Multi-System providing a well-designed solution for door openings Thanks to its side openings, the Header Track can be flexibly installed in three standard door widths. Designed to fit the SORIWA Multi Profile and the SORIWA Core, it enables quick, system-compatible, and completely steel-free installation of door openings in drywall construction.

The SORIWA Core, the SORIWA Multi Profile, and the SORIWA Lintel in use

Can be combined with:

A diagram showing the material of the SORIWA Multi Profile

Available widths:

Material:

85% recycled pulp
15% fibre bonding adhesive 

Product dimensions:

Packaging units:

1 piece

Application:

Doorways

Area of application:

in non-load-bearing interior walls in drywall construction under the climatic environmental conditions of service classes 1 and 2 according to DIN EN 1995-1-1

Downloads:

This product is part of the SORIWA drywall system and is used exclusively in combination with other system components.

Where to buy:

Interested in purchasing our products? Use our dealer locator to find a specialist retailer near you.

If your local retailer does not yet carry our products, please feel free to contact us

Can be combined with:

Your advantages at a glance

SORIWA Advantages Icon

Prefabricated and ready to install

SORIWA Advantages Icon

Adjustable to three door widths

SORIWA Advantages Icon

Negative carbon footprint*

SORIWA Advantages Icon

Safe handling, no sharp edges

*A1-A3 EPD-Kiwa-EE-221187-DE; in accordance with ISO 14025 and EN 15804+A2:2019

The SORIWA Core, the SORIWA Multi Profile, and the SORIWA Lintel in use
The SORIWA Core, the SORIWA Multi Profile, and the SORIWA Lintel in use

The first completely steel-free
stud framework in drywall construction.

Explore the different configuration options and replace the entire stud framework of a drywall partition.

Wall properties

The wall properties of the SORIWA Multi-System have been specifically developed and tested to meet the key requirements for interior construction, including fire behavior, sound insulation, stability, and load-bearing capacity for console loads.

SORIWA Fire behavior icon

Fire Behavior

EI30 and EI60*

SORIWA Sound Insulation Icon

Sound Insulation

Up to 44.2 dB with single-
, and 52.3 dB with double paneling*

Stability

tested and passed

Console loads Icon of SORIWA GmbH

Bracket Loads

0.4–0.7 kN/m
s (= approx. 40–70 kg/m)

*Various wall structures tested; values apply when the exact construction type is followed.

Frequently Asked Questions

Like the SORIWA Multi Profile, the SORIWA Header Track is made from recycled fiber pulp combined with a water-resistant adhesive.

The SORIWA Header Track can be used for the following door opening widths: min. 770 mm, 895 mm, and max. 1,020 mm.